The 21 November 2025 earthquake near Narsingdi (USGS magnitude 5.5, BMD 5.7) killed at least 10 people and injured more than 600. It was a warning, not the worst case.
BNBC 2020 divides Bangladesh into four seismic zones, with zone coefficients from 0.12 to 0.36. Dhaka is in Zone 2; Sylhet, Mymensingh and the north-east are in Zone 4.
On soft soil (site class SD), a building in Dhaka falls in Seismic Design Category D. There, ordinary and intermediate concrete moment frames are not permitted; frames must be "special", with full ductile detailing, or work with shear walls.
The most common local weaknesses are open ground-floor parking (soft storey), short columns, weak concrete, unauthorised extra floors, heavy unanchored rooftop tanks and irregular plans.
Existing buildings can be assessed with drawings, non-destructive tests and analysis, then retrofitted with jacketing, shear walls or bracing.
Before buying a flat, check the approval, the floors built against floors approved, the structural drawings, the soil report and test records.
The November 2025 earthquake: a warning felt across Dhaka
At 10:38 am on Friday 21 November 2025, an earthquake centred near Madhabdi in Narsingdi, roughly 25 to 33 km from Dhaka (reports differ), shook the capital for about 26 seconds. The US Geological Survey put its magnitude at 5.5 and the Bangladesh Meteorological Department at 5.7. The USGS estimated that more than 10 million people in Dhaka felt strong shaking.
At least 10 people died (five in Narsingdi, four in Dhaka and one in Narayanganj) and more than 600 were injured, according to Prothom Alo. Reported deaths included people hit by falling railings and a collapsed wall. The Daily Star called it the deadliest earthquake in Bangladesh in over two decades, and reported damage to about 300 buildings in RAJUK areas, including two adjacent five-storey buildings in Sipahibag, Khilgaon, that tilted.
Within a week, the Chief Adviser directed the housing ministry to form a separate authority to approve buildings across the country, not only in RAJUK's area (The Daily Star Bangla, 27 November 2025).
Is Dhaka safe from earthquake? The risk in plain terms
Dhaka is not doomed, but it is exposed. The honest answer is that safety depends far more on how a particular building was designed and built than on the city as a whole.
Dhaka does not sit on a major fault of its own, but five fault zones are within reach: the Madhupur fault near Tangail, the Dauki fault along the Sylhet region, and three plate-boundary faults. The Daily Star reports that each could produce earthquakes of magnitude 7.0 to 8.5.
A 2016 study in Nature Geoscience found a locked megathrust beneath the Indo-Burman ranges to the east that could generate an earthquake of magnitude 8.2 to 9.0. The researchers could not say when.
A RAJUK study under the World Bank-funded Urban Resilience Project modelled a magnitude 6.9 earthquake on the Madhupur fault. It estimated that 864,619 buildings in Dhaka, slightly over 40 percent, could collapse, with more than 200,000 deaths (Prothom Alo, November 2025). Outside Dhaka, assessments cited by The Daily Star put 70 to 75 percent of Chattogram's more than 380,000 buildings at serious risk, and say over 70 percent of Sylhet's buildings lack seismic design.
These are scenarios, not forecasts. A BUET professor put the real lesson simply in a 2026 Daily Star interview: it is poorly built buildings, not earthquakes themselves, that kill people. That is the part owners can control.
BNBC 2020 seismic zone map: earthquake prone areas in Bangladesh
The Bangladesh National Building Code 2020 was published in the gazette in February 2021 and applies to construction nationwide. Its seismic zoning map divides the country into four zones. Each zone coefficient Z is the peak ground acceleration on rock (in g) for the maximum considered earthquake, taken as a 2 percent chance of being exceeded in 50 years. Design uses two-thirds of that level.
Zone 1 (Z = 0.12, low): the south-west, including Barishal, Khulna, Jashore and Rajshahi
Zone 2 (Z = 0.20, moderate): lower central and north-western areas, including Dhaka, Noakhali, Pabna and Dinajpur, plus the Sundarbans corner
Zone 3 (Z = 0.28, severe): upper central and north-western areas, including Brahmanbaria, Sirajganj and Rangpur
Zone 4 (Z = 0.36, very severe): the north-east, including Sylhet, Mymensingh and Kurigram
Zone coefficients for major towns
Z = 0.12: Barishal, Khulna, Jashore, Rajshahi, Mongla, Bagerhat, Satkhira, Patuakhali
Z = 0.20: Dhaka, Gazipur, Narayanganj, Manikganj, Munshiganj, Cumilla, Feni, Noakhali, Pabna, Faridpur, Chandpur, Dinajpur
Z = 0.28: Chattogram, Cox's Bazar, Rangamati, Bandarban, Narsingdi, Tangail, Bogura, Rangpur, Gaibandha, Brahmanbaria, Sirajganj
Z = 0.36: Sylhet, Moulvibazar, Habiganj, Sunamganj, Srimangal, Mymensingh, Kishoreganj, Netrakona, Jamalpur, Sherpur, Kurigram
Notice that Narsingdi, the epicentre area in November 2025, is in Zone 3 (0.28), while Dhaka next door is in Zone 2. Zones are a design tool, not a promise that shaking stops at a line on the map.
Site class, importance and seismic design category
Site class: the soil under the building
BNBC 2020 classifies the site from the soil in the top 30 m, using shear wave velocity or average SPT N-value: from SA (rock) to SD (loose to medium sand or soft to firm clay) and SE, plus special classes S1 and S2 for very soft or liquefiable soils that need site-specific study. Softer soil amplifies shaking, so the code's soil factor is 1.0 for SA but 1.35 for SD. In one study of 160 borehole sites in Dhaka and Narayanganj, 96 were class SD and 61 class SC. This is why a proper soil test is part of earthquake design.
Importance: what the building is used for
Occupancy Categories I and II (most homes, offices, shops and factories): importance factor 1.0
Category III (for example, places where more than 300 people gather in one area, or schools for more than 250 pupils): 1.25
Category IV (essential facilities such as hospitals with surgery or emergency departments, fire and police stations, and emergency shelters): 1.5
Seismic design category and what it allows
Zone, site class and importance together set the Seismic Design Category (B, C or D), with D the strictest. In Zone 2, a building on SD soil is category D, and so is every Category IV building there. In category D, the code does not permit ordinary or intermediate reinforced concrete moment frames. A concrete frame-only building must be a special moment frame, or the design must use special shear walls or a dual system.
Apartment block in Dhaka: Z x I = 0.20 x 1.0 = 0.20
Same block in Sylhet: 0.36 x 1.0 = 0.36, so 1.8 times the Dhaka design motion before soil and system factors
Hospital with an emergency department in Dhaka: 0.20 x 1.5 = 0.30, so 1.5 times the apartment block
Planning a building and want the seismic design done right from day one? Call +880 1823-017070, email sthapatto@gmail.com or start your project online.
Ductile detailing: what makes an earthquake-resistant building in Bangladesh
BNBC's approach accepts that a major earthquake will damage a building, but aims to keep the damage in chosen places and prevent collapse. That depends on ductility: steel and concrete that bend and stretch instead of snapping. The figures below are from the code's provisions for special moment frames, which concrete frame-only buildings in category D must be.
Columns must be stronger than the beams that frame into them, so beams yield first and the floors stay up. The code requires the combined flexural strength of the columns at a joint to be at least 1.2 times that of the beams.
Hoops, stirrup spacing and 135-degree hooks
Closed hoops at both ends of each beam, over a length of twice the beam depth from the column face
The first hoop no more than 50 mm from the column face
Hoop spacing in those zones not more than a quarter of the beam's effective depth, 8 times the smallest main bar diameter, 24 times the hoop bar diameter, or 300 mm, whichever is least
Hoops closed with 135-degree hooks extending at least 6 bar diameters (and at least 75 mm) into the core; simple 90-degree hooks can open under repeated shaking
Columns and beam-column joints
Column shortest side at least 300 mm, and not less than 0.4 times the other side
Main column steel between 1 and 6 percent of the section
Column bar laps only within the middle half of the column height, never just above the floor
Confining hoops continued through the beam-column joint, and beam bars anchored to the far face of the column core
Well-placed reinforced concrete shear walls, usually around lifts and stairs and at the ends of the building, take a large share of the earthquake force and limit sway. Placing them symmetrically avoids twisting.
Common defects in Bangladeshi buildings
Soft storey: open ground-floor parking
Many apartment buildings leave the ground floor open for parking while the upper floors are filled with brick walls. BNBC defines a soft storey as one with lateral stiffness less than 70 percent of the storey above (extreme below 60 percent). For open parking floors, it says special arrangement is needed and sets out two approaches: a dynamic analysis that includes the infill walls, or designing the open-storey columns and beams for 2.5 times the calculated storey forces, with symmetrical shear walls designed for 1.5 times.
When a partial-height wall, a staircase landing or a mezzanine beam braces part of a column, the free part becomes short and very stiff. It attracts far more shear than designed for and can fail suddenly with diagonal cracks.
Weak concrete and poor workmanship
Low cement, excess water, poor compaction, rusted or under-sized bars and missing hoops undo a good design. Reinforcement should be inspected before every pour and concrete cylinders tested.
Unauthorised extra floors
Adding storeys beyond the approved design adds weight the columns and foundation were never designed for. A July 2026 Daily Star editorial recalled a 2019 finding that over 95 percent of structures in RAJUK's jurisdiction had been built without building approval.
Heavy water tanks and loose non-structural parts
Large rooftop tanks add mass at the worst place. Experts interviewed by The Daily Star in 2026 note that partition walls, false ceilings, glass façades and rooftop tanks often cause injuries, and advise anchoring them. BNBC 2020 includes design rules for attaching non-structural components.
L, T and U-shaped plans, big floor openings and lifts placed at one corner make buildings twist. BNBC treats, for example, re-entrant corners projecting more than 15 percent of the plan dimension as an irregularity, which affects how the building must be analysed. A good architect avoids most of these problems at the concept stage.
Soil and liquefaction: when the ground itself fails
BNBC's seismic provisions assume the soil under the building will not liquefy, settle or slide. That assumption has to be checked. A RAJUK and BUET study places about 55 to 60 percent of Dhaka in the two highest zones of its liquefaction hazard map, and experts say about 90 percent of the city's filled land relies on piles alone, without improving the soil around them (The Daily Star, 2026).
For buildings in category C or D, the code asks the site investigation to assess liquefaction, differential settlement and lateral spreading. On loose filled land, the answer may be deeper piles, ground improvement such as compaction or stone columns, or both.
How to check if my building is earthquake safe
Gather documents. Approved plan, structural drawings with the engineer's name, soil report, completion or occupancy papers. Note the year of design: buildings designed before BNBC 2020 used an older code.
Look for warning signs. Diagonal or X-shaped cracks in columns, beams or walls, spalled concrete with rusting bars, tilting, sagging floors, an open ground floor, or floors added later.
Commission a structural assessment. A qualified engineer starts with a visual survey and as-built measurements.
Test the materials. Non-destructive and minor tests show what is really in the structure. At BUET's April 2026 rates, a rebound hammer test costs Tk 7,000 per location (minimum three), rebar scanning Tk 14,000 per location and an in-situ core with scanning Tk 14,000 per sample, plus a Tk 20,000 field visit fee inside Dhaka.
Analyse against BNBC 2020. The engineer models the building with the real strengths and soil, and recommends: no action, retrofit, or vacate.
A BUET-proposed red, yellow and green colour-coding of Dhaka's buildings is still awaiting full implementation, according to The Daily Star in July 2026, so for now the initiative lies with owners.
Retrofitting: making an existing building earthquake resistant in Bangladesh
Column jacketing: wrapping weak columns in new reinforced concrete, steel or fibre-reinforced polymer to add strength and confinement
New shear walls or steel bracing: especially in an open parking floor, to remove the soft storey
Foundation strengthening: where analysis shows the footings or piles are overloaded
Reducing mass: removing unauthorised floors, heavy rooftop tanks or thick screeds
Base isolation: mostly for important new buildings; it is used at the Rooppur nuclear plant and several metro stations
Cost depends on the building. In November 2025, a BUET civil engineering professor estimated Tk 50 to 60 lakh (Tk 5 to 6 million) to retrofit a six-storey building on a 5-katha plot in Dhaka (Prothom Alo). For public buildings, RAJUK has assessed 3,252 school, college and hospital buildings, recommending 42 for demolition and completing retrofit designs for about 200 (The Daily Star, January 2026).
Buying a flat: earthquake safety checklist
RAJUK (or local authority) approval, and the number of floors built matches the floors approved
Structural drawings signed by a qualified structural engineer, with the code edition stated
The soil test report for that plot, not a neighbouring one
Concrete cylinder and reinforcement test records from construction
How the ground-floor parking was treated: shear walls or bracing, or a design for soft storey forces
Whether the site is on filled or low-lying land, and how the foundation deals with it
No major cracks, honeycombed concrete, exposed bars or visible tilt
Rooftop tanks of sensible size, properly supported, and parapets and railings anchored
What to ask your architect and structural engineer
Which seismic zone, site class and Seismic Design Category apply to this building?
Which structural system are you using: special moment frame, shear walls or a dual system?
How will the open parking floor avoid becoming a soft storey?
Has liquefaction been checked, and why was this foundation type chosen?
What concrete strength and steel grade are specified, and how will they be tested on site?
Who inspects the reinforcement, including 135-degree hooks, before each pour?
How are tanks, parapets, façades and partitions anchored?
How Sthapatto Angon can help
Earthquake resistance starts with the architecture: a regular plan, well-placed cores and walls, and a ground floor that does not become a soft storey. At Sthapatto Angon, our architects and in-house structural engineers work together from the first sketch, so the seismic system is part of the design rather than added later. Our structural team designs RCC, steel, composite and high-rise structures to BNBC 2020, and our MEP engineers coordinate tanks, risers and equipment with the structure.
Seismic design to BNBC 2020: zone, site class, design category and ductile detailing
Coordinated architectural, structural and MEP drawings for approval and construction
Site supervision and quality control through our project management services
Our high-rise and essential-facility work includes the 30-storey Bijoy Tower in Chattogram, a Zone 3 city (designed with a partner firm and submitted for approval in 2023), the 18-storey Hilton Tower in Feni (under construction) and a 100-bed, 6-storey general hospital at the BEPZA Economic Zone in Mirsharai (under construction).
Frequently asked questions
Is Dhaka safe from earthquake?
Dhaka is in BNBC 2020's moderate Zone 2, but nearby faults can produce large earthquakes, and much of the city sits on soft or filled soil that amplifies shaking. Whether you are safe depends mainly on your building: one designed and built to BNBC 2020 on properly investigated soil is far safer than an older, unapproved or altered one.
Which areas of Bangladesh are most earthquake prone?
Zone 4 (Z = 0.36) covers the north-east, including Sylhet, Moulvibazar, Habiganj, Sunamganj, Mymensingh, Netrakona, Kishoreganj, Jamalpur, Sherpur and Kurigram. Zone 3 (0.28) includes Chattogram, Cox's Bazar, the hill districts, Narsingdi, Tangail, Bogura and Rangpur. The south-west, including Khulna, Barishal and Rajshahi, is in Zone 1 (0.12).
What is the seismic zone of Dhaka in BNBC 2020?
Dhaka is in Zone 2, with a seismic zone coefficient Z of 0.20. Gazipur and Narayanganj are also 0.20, while neighbouring Narsingdi and Tangail are 0.28.
How can I check if my building is earthquake safe?
Start with the approved and structural drawings and look for warning signs such as diagonal cracks, exposed rusting bars or added floors. Then have a qualified structural engineer carry out an assessment with material tests and analysis against BNBC 2020.
Can an old building be made earthquake resistant?
Often, yes. Column jacketing, new shear walls or bracing, foundation strengthening and removing excess weight can raise a building's resistance considerably. An engineer's assessment decides whether retrofitting makes sense or whether the building is too weak.
Is ground-floor parking dangerous in an earthquake?
An open parking floor under walled upper floors can form a soft storey, a common cause of collapse. BNBC 2020 says such buildings need special arrangement, such as a dynamic analysis or designing the open storey for 2.5 times the calculated forces, plus shear walls. Ask your engineer how your building handles it.
How much does retrofitting a building cost in Bangladesh?
It depends on the building's condition and size. One BUET professor's November 2025 estimate was Tk 50 to 60 lakh for a six-storey building on a 5-katha plot in Dhaka. A structural assessment comes first, and gives you a costed scope.
ভূমিকম্প প্রতিরোধী ভবন মানে বিএনবিসি ২০২০ মেনে নকশা ও নির্মাণ করা ভবন। বিএনবিসি ২০২০ দেশকে চারটি সিসমিক জোনে ভাগ করেছে: জোন ১ (০.১২), জোন ২ (০.২০), জোন ৩ (০.২৮) এবং জোন ৪ (০.৩৬)। ঢাকা জোন ২-এ, চট্টগ্রাম জোন ৩-এ এবং সিলেট ও ময়মনসিংহ জোন ৪-এ। ২০২৫ সালের ২১ নভেম্বর নরসিংদীর মাধবদীতে ইউএসজিএসের হিসাবে ৫.৫ (বিএমডির হিসাবে ৫.৭) মাত্রার ভূমিকম্পে অন্তত ১০ জন মারা যান। ঢাকায় নরম মাটির (সাইট ক্লাস এসডি) ওপর নির্মিত ভবন সিসমিক ডিজাইন ক্যাটাগরি ডি-তে পড়ে, যেখানে স্পেশাল মোমেন্ট ফ্রেম বা শিয়ার ওয়াল এবং ডাক্টাইল ডিটেইলিং লাগে: শক্ত কলাম ও তুলনামূলক দুর্বল বিম, কাছাকাছি স্টিরাপ এবং ১৩৫ ডিগ্রি হুক। নিচতলার খোলা পার্কিং (সফট স্টোরি), অনুমোদনহীন বাড়তি তলা, দুর্বল কংক্রিট ও ভারী পানির ট্যাংক বড় ঝুঁকি। পুরোনো ভবনে স্ট্রাকচারাল অ্যাসেসমেন্ট ও প্রয়োজনে রেট্রোফিটিং করুন। ফ্ল্যাট কেনার আগে অনুমোদিত নকশা, স্ট্রাকচারাল ড্রয়িং ও সয়েল রিপোর্ট দেখুন। পরামর্শের জন্য স্থাপত্য অঙ্গনে ফোন করুন: ০১৮২৩-০১৭০৭০।